Evs XTnano Version 10.04 - January 2011 Configuration Manual de usuario Pagina 53

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 62
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 52
XTnano – Version 10.04 – Configuration Manual
EVS Broadcast Equipment SA – January 2011
Issue
10.04.A
45
3.12 EVS CONTROLLER SETTINGS
EVS Controller p.6.1
[F1]Effect duration for Take : 00s05fr
[F2]Fast jog : 20x
[F3]PGM Speed/Var Max : 050%
[F4]Lever engage mode : Direct
[F5]Second lever range : -100% <-> +100%
[F6]Recall Clip Toggle : Enable
[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn
3.12.1 EFFECT DURATION FOR TAKE
Possible range: 00s00fr to 20s00fr. Default: 00s05fr
This parameter defines the duration of the transition when using the TAKE key to
chain 2 sequences in PGM+PRV mode.
3.12.2 FAST JOG
Possible values: 01 to 20 times. Default: 20x
This parameter sets the increment of the jump when in Fast Jog mode.
3.12.3 PGM SPEED/VAR MAX
Possible values: 1 to 400%. Default: 50%
During playback, if PGM Spd or VarMax has been enabled in the secondary menu
of the Remote Panel, the lever range will be adapted so that:
The only playback value for any position of the lever other than 0, is the one
specified by this parameter in the setup (PGM Spd mode ON),
Or
The speed range defined by the lever is limited to the value specified by this
parameter (VarMax mode ON).
3.12.4 LEVER ENGAGE MODE
Possible values: Direct (default) / Current Speed
The speed variation depends on the position of the lever.
Vista de pagina 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 61 62

Comentarios a estos manuales

Sin comentarios