Issue 1.10.D XTAccess Version 1.10
User’s Manual
Author: Serge Comes - EVS Broadcast Equipment – July 2009
108
o %BMONTH -> Backup Month
o %BDAY -> Backup Day
o %VCODEC -> Video Codec
23.3.4 REGISTRY SETTINGS
• HKEY_LOCAL_MACHINE\SOFTWARE\EVS Broadcast Equipment\Common \
MinFieldsToWriteBeforeRefInCEDB: Specific setting to wait a specific number
of fields before referencing clips into CleanEdit.
• HKEY_LOCAL_MACHINE\SOFTWARE\EVS Broadcast Equipment\Common
\FileWriter NoBuffering: Specific setting to transfer a file without any
buffering. Recommended for writing on a MacOS workstation via network
(SMB). (default value = 0)
• HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max
Transfer Rate: Maximum transfer rate (Bytes/second) for the total amount of
backup jobs (all together).
• HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Safe
Train Backup: protection to avoid reaching the head of a train during backup of
train:
o 0: Active
o 1: Not Active
23.3.5 WORKFLOW WITH TRANSCODING ON THE FLY
You can use XTAccess to generate the low res for CleanEdit.
1. XTAccess will receive a request for backup file from IPD.
2. XTAccess will create the backup for example DNxHD and will transcode it
on the fly for example in MPEG1
3. XTAccess will reference these two files as High/Low clip in CleanEdit
Comentarios a estos manuales