Issue 5.8.B IPDirector Version
5.8
User Manual
Part 4: Ingest
EVS Broadcast Equipment – July 2010
24
Pressing the Stop button will have the following effect, depending on ingests of
the corresponding channel:
Ingest Type Action of Stop button
No ingest No action.
Growing clip Stops the recording of the growing clip.
Recording ingest Stops the recording of the ingest.
Growing clip and
recording ingest
overlapped
Stops the recording of the selected clip.
If no clip is selected, the Stop button is unavailable.
2.6.3 RULES WHEN USING START AND STOP BUTTONS
Pressing the Start button starts the recording of a growing clip or a stream on
all the selected channels and all the channels ganged with the selected
channels.
Pressing the CTRL key + the Start button starts the recording of a growing clip
or a stream only on the selected channels.
Pressing the Stop button stops the recording of the clip or the stream on all the
selected channels and all the channels ganged with the selected channels.
Pressing the CTRL key + the Stop button stops the recording of the clip or the
stream only on the selected channels.
2.6.4 REMAINING CAPACITY
The information about remaining capacity is displayed for each sub-track of an
ingest channel.
This can be displayed as time or storage capacity according to the settings
defined in Tools > Settings > Ingest Scheduler > Remaining Capacity. Refer to
section 2.8 ‘Settings’ on page 27 for more information.
If t
he remaining space/time falls below the Capacity Warning threshold defined in
the settings, the Remaining Capacity field is shown with a red background.