Issue 10.01.I EVS Multicam Version 10.01 – Configuration Manual
EVS Broadcast Equipment SA – October 2009
62
Audio p.5.2
[Menu]Quit [Clr+F
_
]Dft [F9]PgUp [F0]PgDn
This page is intentionally left blank and is reserved for future developments.
3.13 EVS CONTROLLER SETTINGS
EVS Controller p.6.1
[F1]Effect duration for Take: 00s05fr
[F2]Fast jog : 20x
[F3]PGM Speed/Var Max : 50%
[F4]Lever engage mode : Direct
[F5]Second lever range : -100% <-> +100%
[F6]Recall clip Toggle : Enable
[Menu]Quit [Clr+F
_
]Dft [F9]PgUp [F0]PgDn
3.13.1 EFFECT DURATION FOR TAKE
Possible range: 00s00fr to 20s00fr. Default: 00s05fr
This parameter defines the duration of the transition when using the TAKE key to
chain 2 sequences in PGM+PRV mode.
3.13.2 FAST JOG
Possible values: 01 to 20 times. Default: 20x
This parameter sets the increment of the jump when in Fast Jog mode.
3.13.3 PGM SPEED/VAR MAX
Possible values: 1 – 400%. Default: 50%
During playback, if PGM Spd or VarMax has been enabled in the secondary menu
of the Remote Panel, the lever range will be adapted so that:
the only playback value for any position of the lever other than 0, is the one
specified by this parameter in the setup (PGM Spd mode ON)