EXAMPLE
Users can select all types of GPIs. The behaviour varies accordingly:
Before the
IN
On Replace
IN
Between IN
and OUT
On Replace
OUT
After the
OUT
High Low
High
High
Low
Low
Low High
Low
Low
High
High
High
Pulse
Low
High Pulse
Low
High Pulse
Low
Low
Pulse
High
Low Pulse
High
Low Pulse
High
4.15 GPI OUT SETTINGS
GPI OUT Setting p.8.4
[F1]GPI Delay : Disable
[F2]GPI Out Advance : Disable
[F3]GPI Pulse Duration : 01s00fr
[Menu]Quit [Clr+F
]Dft [F9]PgUp [F0]PgDn
4.15.1 GPI DELAY
Possible values: Disable (default, immediate reaction) / 00s01fr to 02s00fr
This parameter defines the delay for the XT[2] server to react to the
reception of a GPI trigger.
4.15.2 GPI OUT ADVANCE
Possible values: Disable (default) / 00s01fr to 02s00fr
Possible values: up to 2 seconds, frame by frame (like GPI delay)
When a GPI out advance setting is set (for instance 2 fr.), the GPI out is
sent 2 frames in advance.