Vista de pagina 79
The following screenshot presents the page 1 of the Channels tab, where the port settings
are available in the server-based application, and highlights the port settings field group:
RS422 #1 - #6
Description Specifies what type of device/controller is connected to each
RS422 port of the EVS server.
Values The following values can be available if the required license
codes are active:
'EVS Remote' for LSM Remote Panel (code between 103
and 109).
'EVS Remote' for XSense Remote Panel (code between
103 and 109 or code 96)
'EVS IPDP' (code 120 or 121)
'Sony BVW75' (code 118)
'XtenDD35' (code 118)
'Odetics' and 'Odetics FK' (code 119)
'VDCP' and 'VDCP FK' (code 119)
'EVS AVSP' (code 120 or 121)
'Edit Rec' (code 122)
'Linx' (code 123)
'Touch screen'
Default On port #1 (only): IPDP
Rules The following rules are applicable for assigning the following
controlling devices to RS422 ports:
In all base configurations that rely on an EVS Remote
Controller, the 'EVS Remote' shall always to be assigned
to the first allocated RS422 port.
A touch screen can only be assigned to port 6.