10.05.D
XT33 Series DISK RECORDERVersion 10.05 - Software Technical Reference
EVS Broadcast Equipment SA July 2011
64
2.4 INITIALIZING THE MICROCODE
The final step is the initialization of the microcode.
If the first line of the application is flashing with the message "Disk #x has been
disconnected in operation", the system will display the message: "Disk to be
disconnected: x". The system will work on 4 disks. Raid function is turned off.
The message "Init board: nb blocks of size kBytes. Audio:aud DiskUse:use%" is
displayed.
where
nb is the number of blocks used on the system
size is the size in kBytes of a block on a disk
aud is ON/OFF
use is the operationalDiskSize in %
If the system must load tables (no clear clips done in EVS main menu), the
message "Loading tables …" will appear.
When the initialization is complete, the system displays the message "H3X board
initialized" and the system is ready. If an error occurs, the message "ERROR
(0xErr): H3X board not correctly initialized" is displayed. The error (Err) are
detailed in the following section.
Possible Errors
If an error is detected while loading tables, the following message is displayed: "
LOAD <TAB>LE ERROR state = [St]" where ‘St can be:
1. Block error A disk error occurred while loading the table on
hard disks. Maybe a disk failure. Replace disks.
2. Cache overflow
error
No more blocks available in cache. Algorithm
problem. Contact EVS.
3. Checksum error This can occur if a disk has been replaced and
data not rebuilt on it. Rebuild data on the disk to
clear the message. If no disk has been replaced,
try to re-
start the server to clear the error
message. If it does not resolve it after a few re-
start, a clear clip will be necessary.
4. Signature error The signature on the table file is not found in the
header file. Try to re-start the server to clear the
error message. If it does not resolve it after a few
re-start, a clear clip will be necessary.