10.05.D
XT33 Series DISK RECORDERVersion 10.05 - Software Technical Reference
EVS Broadcast Equipment SA July 2011
74
LTC Description Default
Values
Peak limits
(sec)
Period of time (in seconds) of continuous timecodes
after which a break in timecodes in the recorded
material will generate a peak alert. When a peak alert
is generated, the value in Peak Alerts field is
incremented by one.
10
Frequency
alert
Number of frequency alerts generated for the recorder
since the last start of the server.
A frequency alert is generated when X timecode
jumps have been detected in Y seconds.
The X value is defined in the Frequency Number field.
The Y value is defined in the Frequency Time field.
In this case, this field is automatically incremented by
one.
0
Frequency:
Number
Number of timecode jumps detected for the recorder
after which a frequency alert can be generated.
10
Frequency
Time
Period of time (in seconds) after which a frequency
alert can be generated.
50
VITC Default
Values
VITC jumps
Number of timecode jumps calculated in the VITC
timecode jump table for the given recorder since the
last start of the server.
1
VITC
threshold
Number of continuous timecodes to be received, after
a break in VITC timecodes in the recorded material, in
order to create a new record in the VITC timecode
jump table.
50